Skip to main content

Local Electrician Manchester

Local Electrician 24-7 Ltd | Menu Navigation

Electrical safety reports

EICR certificates for Manchester homes and businesses

A full inspection of your electrical installation, tested properly and written up in plain English — so you know exactly what is safe, what needs attention, and why.

  1. Book online Choose your property and a time, then pay securely — right here.
  2. We inspect & test Your electrician tests every circuit we can safely reach.
  3. Get your certificate Your EICR lands in your account dashboard, ready to download.
Local Electrician 24-7 engineer testing a consumer unit during an EICR inspection NICEIC Approved Contractor
Clear written reportEvery code explained
5-star reviewsFrom Manchester customers

Do you need one?

Who an EICR is for, and how often

The right interval depends on the property and how it is used. If you are not sure where you stand, send us the details and we will tell you plainly.

  • Letting agent and electrician discussing a rental property inspection
    Landlords & agents

    Every 5 years (England, private rented)

    A legal duty, not a recommendation

    By law, privately rented homes in England need an EICR at least every five years, shared with tenants.

    • Report before a new tenancy begins
    • Access arranged around tenants
    Landlord services
  • Electrician talking a homeowner through electrical safety findings
    Homeowners

    Around every 10 years (general guidance)

    Peace of mind, or before you buy

    Advised roughly every ten years — or sooner when buying, extending, or if the wiring is old.

    • Older wiring and fuse boards assessed
    • Priorities explained, not upsold
    Book a homeowner EICR
  • Commercial electrician reviewing a distribution board with a business client
    Commercial

    Typically every 5 years (risk dependent)

    Fixed wire testing for premises

    Intervals depend on your premises and insurer. We phase testing so you can keep trading.

    • Out-of-hours testing where needed
    • Documentation for insurers
    Commercial services

Intervals above are general guidance and the legal position differs across England, Scotland and Wales. Tell us your property type and we will confirm what applies to you.

Book your EICR — from £69

Not sure which applies? Call 07999 553 838

Inside the inspection

What actually gets checked

An EICR mixes a close visual inspection with instrument testing. These are the six areas we work through on a typical property.

  1. Consumer unit & protection

    The board’s condition, its protective devices, and RCD protection where it’s needed.

    Inspected
  2. Earthing & bonding

    The main earth, and bonding to gas and water pipes — a common finding in older homes.

    Inspected & tested
  3. Insulation resistance

    Every circuit tested for worn or damaged insulation that could cause shocks, trips or fire.

    Tested
  4. Loop impedance & RCD times

    Faults must clear fast enough, and RCDs must trip within their set times.

    Tested
  5. Accessories & fittings

    Sockets, switches and lights checked for damage, scorching and loose terminals.

    Inspected
  6. Cabling & previous work

    Cable condition and protection, and any DIY or non-compliant changes.

    Inspected

Reading your report

What the codes on your report mean

Anything we find gets one of four codes. Here’s what each one means for you — and which ones fail a report.

SatisfactoryNo C1, C2 or FI — only C3s, or nothing at all.

UnsatisfactoryAny C1, C2 or FI on the report.

  1. C1 Fails the report

    Danger present

    Someone could get hurt right now.

    We make it safe on the day wherever we can.

    Example: a damaged socket with live parts you can touch.

  2. C2 Fails the report

    Potentially dangerous

    Not dangerous yet, but it could become so.

    Needs putting right urgently.

    Example: a circuit with no earth connection.

  3. FI Fails the report

    Further investigation

    Something couldn’t be fully checked on the day.

    Needs a closer look without delay — often the cheapest code to sort.

    Example: a circuit that couldn’t be traced to its origin.

  4. C3 Doesn’t fail

    Improvement recommended

    Not unsafe — just not up to today’s standard.

    Your choice: C3s on their own never fail a report.

    Example: no RCD on an older circuit that met the rules when it was installed.

Book your EICR — from £69

Already have a report? Call us and we’ll talk you through it.

How it works

From booking to certificate

Four straightforward steps, with no surprises in the middle.

  1. Tell us about the property

    Property type, rough age, number of fuse boards and your postcode. That is usually enough for a firm price.

  2. Inspection & testing

    We work circuit by circuit, isolating the supply in stages and recording every test result as we go.

  3. Your report, explained

    You receive the full report and a walkthrough of anything coded — what it means, how urgent it is, and what it would take to fix.

  4. Remedial work, if needed

    Anything that needs putting right is quoted separately and prioritised. No pressure to do the optional items.

From recent inspections

Testing and reporting, on real jobs

See more work
  • Insulation resistance test reading taken during an electrical inspection VerificationRecorded test results
  • Consumer unit being inspected in a domestic property InspectionConsumer unit check
  • Circuit testing at a distribution board TestingCircuit by circuit
  • Metering and distribution equipment after upgrade work RemedialsBoard upgrade
  • Lighting circuit work carried out after an inspection Follow-upLighting circuit

Watch an inspection

What testing actually looks like

Short clips from real jobs — so you know what to expect before we arrive.

  • Inspecting a distribution boardWorking through the board circuit by circuit
  • RCD testingTrip times read off the tester
  • Testing and recordingReadings taken and written up as we go

Straight answers on cost

Clear prices, booked online

The price goes by the size of the property, and you see the final figure before you pay — VAT included, no call-out fee, nothing added once we are through the door.

Domestic EICR from £69 VAT included
Studio
£69
1 bedroom
£89
2 bedrooms
£99
3 bedrooms
£109
4 bedrooms
£119
5+ bedrooms
£129

One fuse board included — each extra board £50.

  • Full inspection and testing of the fixed installation
  • Every accessible circuit tested and recorded
  • Your EICR report, with every code explained
  • No call-out fee and no travel charge

Non-domestic EICRs are priced by the number of circuits, from £140, and PAT testing starts at £59 — both can be booked online. Remedial work, if the report calls for any, is quoted separately and itemised — never added on without your say-so.

An older fuse box alongside a modern replacement consumer unit
Remedials quoted separately If your report comes back unsatisfactory, you get a clear, itemised price for the work — never a bundled surprise.

Google feedback

What customers say about our testing work

Punctual, tidy and clear about what was found — the three things that come up most.

Book your EICR — from £69

Rated 5 stars by customers across Manchester

EICR questions

Before you book

The questions we are asked most about inspections. If yours is not here, call or send the form.

How much does an EICR cost?

A domestic EICR starts at £69 for a studio, then £89 for one bedroom, £99 for two, £109 for three, £119 for four and £129 for five or more. One fuse board is included; each extra board is £50. Non-domestic EICRs are priced by the number of circuits, from £140, and PAT testing starts at £59. Every price includes VAT, the inspection, the testing and your report, with no call-out fee, and you see the final price before you pay. If the report identifies remedial work, that is quoted separately and itemised.

How long does an EICR take?

For an average home, often two to four hours. It depends on the number of circuits, how accessible the wiring is and what we find along the way. Larger or multi-board properties take longer, and we will tell you what to expect when we book.

Will the power be off the whole time?

Not the whole time, but the supply does need isolating for parts of the testing. We work in stages and can plan around things like home working, freezers or medical equipment if you tell us in advance.

Do I need to be at the property?

Someone needs to provide access, but it does not have to be you — we regularly work with tenants and agents. We do need access to the consumer unit and, ideally, to every room so that accessories and fittings can be checked.

What happens if my report is unsatisfactory?

It means one or more items were coded C1, C2 or FI. We will explain each one, tell you how urgent it is, and give you an itemised quote for putting it right. Anything immediately dangerous is made safe at the time wherever possible. You are never obliged to use us for the remedial work.

How long is an EICR valid for?

The report itself recommends a date for the next inspection. For privately rented homes in England that is at least every five years; owner-occupied homes are generally advised around every ten. A change of occupancy or significant alteration can bring that date forward.

Is an EICR the same as a landlord safety certificate?

People often use the phrases interchangeably. The EICR is the report on the fixed wiring that satisfies the electrical safety duty for rented homes. It is separate from a gas safety check, and separate again from PAT testing of plug-in appliances.

Prefer to just ask?Call Essi on 07999 553 838

Call now

Local coverage

EICR inspections across Greater Manchester

Send your postcode if your area is not listed — we will confirm availability straight away.